VIGIL3 Transformerless Amplifiers

Transformerless Amplifiers for VIGIL3 voice alarm systems are powerful, compact and robust and form part of the VIGIL3 Voice Alarm system.

VIGIL3 Amplifiers form part of our Voice Alarm range of products. They use new transformerless technology and are compact, efficient, and robust.

With 5 modules in the range: Dual 75 Watt, Quad 75 Watt, Dual 150 Watt, Quad 150 Watt, and Dual 300 Watt, each amplifier has a built in power supply and floating transformerless output for increased efficiency. Compared with our VIGIL2 units, they are up to an incredible 66% lighter on a like-for-like basis.

Although amplifier power has increased and the power supply is incorporated, the units themselves are significantly reduced in size. The more compact size results in less rack space – up to 12 x 150 Watt outputs per 12U – which means the rack footprint is reduced. This means that battery size on a Watt by Watt basis is also reduced, all helping with the cost efficiency and space-saving both of which are valuable assets for many companies.

 

  • Floating, transformerless technology negates the need for heavy and cumbersome transformers
  • Each unit is up to 66% lighter than its equivalent predecessor
  • Far less copper required during manufacture
  • Increased space within the unit for improved airflow
  • Increased power in a smaller sized unit when compared to alternatives
  • Fit up to 1800 Watts of power in one 2U rack space
  • Each unit includes a built-in power supply – freeing up valuable rack space
  • Sleep mode which operates, not only when the system is running on batteries, but also when it is running from mains power

BV300D / BV150D / BV075D
Amplifier – transformerless
Dual 300W / Dual 150W / Dual 75W
142mm x 75mm x 311mm
3.1 kg / 2.3 kg / 2.3 kg

BV150Q / BV075Q 
Amplifier
Quad 150W / Quad 75W
142mm x 75mm x 311mm
3.1 kg / 3.1 kg 

BV3MF
Amplifier mainframe
Holds up to 3 VIGIL3 amplifiers

Safe & Compliant

EN54 Certified

BS EN 54: Fire Detection & Fire Alarm Systems, is a mandatory standard that specifies requirements and laboratory testing for every component of fire detection and fire alarm system.

UKCA UK Conformity Assessed

UKCA (UK Conformity Assessed) marking on products replaces CE marking in the UK and requires that certification of construction products, such as VACIE / Voice Alarm Control & Indicating Equipment is performed by a UK-based approved body.

British Standards BS5839-8 Code of Practice
BS 5839-8 is a BSI Standards Publication code of practice providing recommendations for the design, installation, commissioning, and maintenance of voice alarm systems that automatically broadcast speech or warning tones, in response to signals from their associated fire detection and fire alarm systems.

Key Benefits

VIGIL3 Voice Alarm System

Fast. Powerful. Flexible. VIGIL3 is built with a fault-tolerant ethernet backbone, no ethernet switches are required and there are no licence fees. From a single rack to large distributed systems with hundreds of outputs, use wall mount or rack mount for outputs in any combination.

Documentation & Downloads

Looking for something in particular?

Search our full database of downloads and documentation

VIGIL3 Product Range

Voice Alarm

VIGIL3 Amplifiers

Transformerless amplifiers, modular, energy-efficient and powerful. Range includes dual & quad amplifier options.

Voice Alarm

VIGIL3 Battery Charger

Compact module continually monitors system backup batteries & charges them whenever necessary.

Voice Alarm

VIGIL3 Audio Output Module

With VIGIL3 there is no need for the conventional ‘router-style’ control. Supports up to 8 audio outputs – network up to 100 units.

Voice Alarm

Powerful stand-alone, wall-mounted PAVA system. Ideal for fitting into building risers or places where space is limited.

Voice Alarm

VIGIL3 Audio Input Module

6-band parametric EQ and programmable priority for each input. Configure every input from a single point on the VIGIL3 network.

Voice Alarm
Built on a dedicated, fault-tolerant, Ethernet backbone with a range of networking options.
Voice Alarm

VIGIL3 Line Monitoring

All critical signal paths of a voice alarm system must be fully monitored & faults automatically indicated on key parts of the system.

Audio Loudspeakers

Loudspeakers

Powerful high-clarity loudspeakers for public address and voice alarm systems for both indoor and outdoor installations.

Microphones for Voice Alarm (VA) & Public Address (PA)

Touch Control

User-configurable, large format touchscreen Graphical User Interface (GUI) enables graphical control of our VIGIL3 and Eclipse5 systems. Upload logos, background images, edit buttons and much more.

Touch Control

Easy-to-use microphone with a touch sensitive screen for full control of a VIGIL3, VIGIL2, Eclipse4 or Eclipse5 system. Multi-function: NFC log in, select & route background music, emergency control mode and more. 

Fire Microphones

Baldwin Boxall Emergency Fire Microphones are housed in a robust, lockable steel enclosure and include a rugged, fist-held microphone console. Wall mountable and rack mounting units available.

Paging Microphones

BDM400 range of intelligent PA microphones with a variety of features to suit all installations. Suitable for connection to any of our voice alarm or public address systems – including VIGIL3 & Eclipse5.

Ambient Microphones

Ambient Noise Sensors (ANS) continually monitor the noise level (in a zone/area) and automatically adjust the volume of system broadcasts to that area – thus ensuring audibility at all times. Connect as part of any of our voice alarm systems.

Room Panels

Control Panels enable local control of audio facilities such as volume adjustment, music source selection and microphone input.

Make An Enquiry

Make An Enquiry (#13)