OmniCare Control Panel

OmniCare EVC Control Panel for two-way communication with the outstations on the system.

OmniCare is a loop-wired, addressable Emergency Voice Communication system enabling Disabled Refuge, Fire Telephones, Combined (Disabled Refuge & Fire Telephone) Outstations, Steward Telephones and Emergency Assistance/Toilet Alarms to be connected to a single panel.

OmniCare can be easily networked with multiple control panels on a system. This enables local zone/area control with gatehouse or management control on a master panel.

The Control Panel features an output for an external call indicator, designed for use in situations where the control panel is mounted in an unmanned area. Using this output, a remote indicator can be fitted in a location where it is visible and can be heard such as in a reception area.

The output has a programmable delay feature so that calls answered at the panel are not relayed to the remote indicators.

Panel options include sizes from four-way up to 127-way and are supplied with the relevant batteries for backup should the mains power fail. All panels are available with either grey or stainless steel finish. 

Designed to be wall mounted, with option to either flush mount (separate bezel required) or rack mount (rack mounting kit required).

OmniCare has been designed and built to meet BS5839-9:2021 and BS8300-2:2018 (for the emergency assistance/toilet alarm).

OmniCare EVC system is an alternative to our popular (radial-wired) CARE2 EVC system.

 

Features
  • One master and multiple slave panels can be linked on one system (panels are configured on installation).
  • Control Panels are supplied as surface mountable units with the option to flush mount by using a, separately available, bezel.
  • Each Control Panel features a lockable glazed door.
  • Control Panel sizes from 4 to 127-way available with a choice of grey or stainless steel finish.
  • The Control Panel features an output for an external call indicator. The output includes a programmable delay feature. (Remote lamp/buzzer available – code BVOCCA.)
  • Link to fire detection system prevents hoax calls from disabled refuge (toilet alarms and fire telephones remain active). Can be completely or partly overridden.
  • Indicators for: in use/occupied, call, fault, power, charger and speech volume.
  • Handset volume control.
  • ‘Listening’ facility.
  • Communication is speech steered (disabled refuge remotes) and full duplex speech (fire telephones and emergency telephones).
Remote Lamp & Buzzer (BVOCCA)
  • For areas where master console is not manned permanently.
  • Indicates a call to master control panel.
  • Single gang unit with red LED, sounder and buzzer mute.
  • Stainless steel finish.
  • Settings to allow call delay of up to 90 seconds (carried out at master console).

BVOC4M / BVOC8M / BVOC16M / BVOC32M
4 / 8 / 16 / 32-way Control Panel
Grey 
Wall mount or flush mountable with bezel
Rack mount kit option
410mm x 290mm x 200mm
9.16 kg / 9.16 kg / 14.5 kg / 14.5 kg

BVOC4MS / BVOC8MS / BVOC16MS / BVOC32MS
4 / 8 / 16 / 32-way Control Panel
Stainless steel
Wall mount or flush mountable with bezel
Rack mount kit option
410mm x 290mm x 200mm
9.16 kg / 9.16 kg / 14.5 kg / 14.5 kg

BVCRFB2 / BVCRFB2S
Bezel for flush mounting 4 to 32-way panels
Grey / stainless steel 
461mm x 450mm with 25mm radius (c/o 420W x 300H)
1 kg

BVCRM3
Rack mount kit for 4 to 32-way panels
1 kg

BVOC48 / BVOC64 
48 / 64-way Control Panel
Grey 
Wall mount or flush mountable with bezel
Rack mount kit option
410mm x 455mm x 200mm
14.6 kg / 14.6 kg
Supplied with separate Battery Box (BVOBATT) 

BVOC48S / BVOC64S
48 / 64-way Control Panel
Stainless Steel
Wall mount or flush mountable with bezel
Rack mount kit option
410mm x 455mm x 200mm
14.6 kg / 14.6 kg 
Supplied with separate Battery Box (BVOBATT)

BVCRFB1 / BVCRFB1SS
Bezel for flush mounting 48 to 64-way panels
Grey / stainless steel 
461mm x 506mm with 25mm radius (c/o 420W x 465H)
1 kg

BVCRM1
Rack mount kit for 48 to 64-way panels
1 kg

BVOC80 / BVOC96 / BVOC112 / BVOC128
80 / 96 / 112 / 127-way Control Panel
Grey 
Wall mount or flush mountable with bezel
Rack mount kit option
410mm x 777mm x 200mm
15.5 kg / 16 kg / 21.85 kg / 21.85 kg
(Battery backup – contact our sales team) 

BVOC80S / BVOC96S / BVOC112S / BVOC128S
80 / 96 / 112 / 127-way Control Panel
Stainless steel
Wall mount or flush mountable with bezel
Rack mount kit option
410mm x 777mm x 200mm
15.5 kg / 16 kg / 21.85 kg / 21.85 kg
(Battery backup – contact our sales team) 

BVCRFB3 / BVCRFB3S
Bezel for flush mounting 80 to 128-way panels
Grey / stainless steel 
461mm x 827mm with 25mm radius (c/o 420W x 787H)
1 kg

BVCRM2
Rack mount kit for 80 to 128-way panels
1 kg

KEYBVE
Spare Key for panel

BVOCCA
Remote Lamp Buzzer
Stainless steel
85mm x 85mm

BVOBATT / BVOBATT2
Battery box enclosure
Grey
410mm x 290/600mm x 200mm
6.4 kg / 13.56 kg

Safe & Compliant

British Standards BS5839-9 Code of Practice

BS5839-9 is a code of practice for those who install, maintain and commission EVC systems, giving guidance on how to install an effective system as part of a fire detection and alarm system covering all components including wireless.

British Standards BS9999 Code of Practice

BS9999 is a BSI Standards Publication providing guidance for fire safety in the design, management and use of buildings. It includes the provision of evacuation methods and placement of EVC systems.

Key Benefits

Documentation & Downloads

Looking for something in particular?

Search our full database of downloads and documentation

OmniCare Control Options

Loop Wired EVC
4-127 way options in either Grey or Stainless Steel finish. Surface mount or flush mount with the optional bezel.
LOOP WIRED EVC
Touchscreen Control adds further flexibility to the OmniCare Emergency Voice Control (EVC) system.
Loop Wired EVC
OmniCare is a loop-wired Emergency Voice Communication (EVC) system with varying style remotes on one loop.

OmniCare & OmniCarePLUS Outstations

Loop Wired EVC

OmniCare Disabled Refuge Outstations

Type B outstation. Two-way, hands-free voice communication unit for disabled refuge areas. Standard & Advance versions available.

Loop Wired EVC

OmniCare Steward Telephones

Type A outstation. Two-way voice communication Emergency Steward Telephone, typically used where crowd control is required, such as Stadia.

Loop Wired EVC

OmniCare Fire Telephones

Type A outstation. Two-way emergency voice communication Fire Telephone, typically used by Fire Officers during the evacuation of a building. 

Loop Wired EVC

OmniCare Combined Outstations

Type C outstation. Combined Fire Telephone & Disabled Refuge outstation – two methods of communication at a single point. 

Loop Wired EVC

Assistance Alarm for EVC

Emergency Assistance Alarm solution for toilets for the OmniCare EVC system.

EVC System Options

Loop Wired EVC

OmniCare EVC system is fully expandable and networkable, enabling up to 127 outstations. The first of its kind when introduced as a combined EVC system and now leads the way with installations throughout the world.

LOOP WIRED EVC

OmniCarePLUS makes it possible to install especially large Disabled Refuge/Fire Telephone Emergency Voice Communication (EVC) systems with up to 2,048 outstations on a single loop-wired system.

Radial wired evc

CARE2 is our radial-wired EVC system featuring monitored bidirectional communication outstations and has been developed to provide an alternative EVC option to our popular loop-wired OmniCare systems.

Make An Enquiry

Make An Enquiry (#13)

Scroll to Top